In general, the locomotor depressant and discriminative stimulus effects have been observed at doses that do not produce adverse effects, although tremors were observed upon handling in mice that received JWH-210 (Gatch et al., 2016), and 5F-AMB produced sustained vocalization and convulsions in rats (Gatch et al., 2018

Figure 1.
Each training session lasted a maximum of 10 min, and the rats could earn up to 20 food pellets. Thirty minutes prior to the training sessions, rats received an injection of either vehicle or Δ9-THC and were subsequently placed in the behavior-testing chambers, where food (45-mg food pellets; Bio-Serve, Frenchtown, NJ) was available as a reinforcer for every ten responses (FR10) on a designated injection appropriate lever. A houselight was centered over the hopper close to the ceiling and was illuminated only when the levers were active. Each dose range included doses that were without effect to those producing at least 50% depression compared to vehicle control. Twenty-four male Sprague-Dawley rats were obtained from Envigo (Houston, TX). Male ND4 Swiss–Webster mice were obtained from Envigo (Houston, TX) at approximately 8 weeks of age and maintained in the University of North Texas Health Science Center (UNTHSC) animal facility for two weeks prior to testin


All of the compounds tested in the present study depressed locomotor activity as is typical for other synthetic cannabinoids (see review by Wiley et al., 2017). Average horizontal activity counts/10 min as a function of time (10 min bins) and dose. Depressant effects of 1.33 mg/kg were observed within 10 min following administration and peak depressant effects were 4F ADB observed between 0–30 min. Duration of the locomotor depression increased over dose from 30 min following 0.1 mg/kg to 2.5 h following 1 mg/k


Morris water maze test was performed to evaluate the changes in learning and memory function. Only a few case reports about the dangers of some synthetic cannabinoids due to neurotoxicity have been published (Cohen et al., 2012; McGuinness et al., 2012; Harris and Brown, 2013; Hermanns et al., 2013). In addition, the lack of information about neurotoxicity of synthetic cannabinoids could allow abusers consume those substances undiscerningly. However, slight structural changes might cause biochemical properties including dependence liability and neurotoxicity. The substances used in the present study both possess naphthoylindole moiety as their parental structure. (B) The ratio of damaged cells containing pyknotic or condensed nuclei and low hematoxilin affinity to total cells were calculated in nucleus accumben


Separation of compounds was performed on a 2.1 mm×100 mm, 1.7 4F ADB μm particle size ACQUITY Torus™ DIOL analytical column (Waters) with guard cartridge. Measurements were performed by an ACQUITY UPC2 supercritical fluid chromatography system (Waters) coupled with a Xevo TQ-S Triple Quadrupole Mass Spectrometer (Waters). During the death scene examination, multiple cigarette butts without filters were found in an ashtray; also found were alcohol bottles, an unopened box of nebivolol-containing drug, and 18 g of unrecognizable herbal residue in a cigarette box.
Data concerning the combined effects of SCRAs and other substances are highly limited, which renders forensic evaluation of possible overdose cases difficult . The threshold SCRA concentration for fatal overdose can be estimated ng/mL level (0.37–4.1 ng/mL according to the reported cases) in cases in which 1.5–2.5 g/L of ethanol is present in the blood. The victims were brothers who were both found deceased after consuming 4F-MDMB-BINACA and ethanol. These confusing shorter names were not scientifically adopted but were used by websites selling the drugs to the public. Monitoring metabolism of synthetic cannabinoid 4F-MDMB-BINACA via high-resolution mass spectrometry assessed in cultured hepatoma cell line, fungus, liver microsomes and confirmed using urine samples. This article does not contain any studies with human participants or animals performed by any of the author


High resolution mass spectrometry such as LC-QTOF-MS allows the detection and identification of a broad spectrum of recreational drugs, including new psychoactive substances. A point-of-care drugs of abuse (DOA) test was initially performed on the urine of the patient. He confirmed drinking 750 ml energy drink without any further consumption of food and using an e-cigarette from Gaziantep, Turkey 10 seconds before the onset of his first symptoms. He usually smokes a pack of cigarettes a day and sometimes smokes e-cigarettes. Combined with non-specific, transient symptoms, clinical recognition of SCRA intoxication is challenging .
Data availability
The intensity is plotted against the retention time for both chromatograms, demonstrating the 4F ADB presence and elution profiles of nicotine and ADB-BUTINACA in the analysed vape liquid sample. LC-QTOF-MS Chromatograms of Nicotine (Top) and ADB-BUTINACA (Bottom) in the Vape Liquid used by the patient. The LC-QTOF-MS analysis showed that the e-liquid contained nicotine and ADB-BUTINACA (Fig. 1). Because the point-of-care DOA test is generally not able to detect synthetic recreational drug substances, the liquid of the e-cigarette was thereafter screened using liquid chromatography-quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) on the Waters™ Xevo G3 QTOF MS system. After eating a light meal and drinking caffeinated sports drinks at the ER, the nausea complaints of the patient were reduced and the patient was discharged hom